ENVIRONMENTAL MONITORING
DUST MONITOR – D53

D53

The D53 is an industrial dust and air quality monitor that offers real-time monitoring of particulate levels and surrounding environmental conditions to identify unhealthy conditions early on, to act quickly.

The D53 supports proactive dust management, giving sites better visibility of exposure risk to help improve workplace safety, environmental awareness, and overall control.

WHY IS DUST MONITORING IMPORTANT? 

Airborne dust and silica particulates (specifically) pose serious risks to health and safety in industrial environments. Prolonged exposure to PM1, PM2.5, PM4, and PM10 can cause chronic respiratory disease, cancer, cardiovascular damage, and other life-threatening illnesses.

ENVIRONMENTAL MONITORING

DUST MONITOR D53

REAL-TIME RELIABLITY

  • Easy to read data readings and range limits displayed on a TFT display
  • Response time <60 secDetection limits (PM10) 0.01 to 1000mg/m3
  • Sensor range between 0.30µm to 10µm

ROBUST & RELIABLE

  • Configurable to activate automated ventilation or dust suppression system
  • Operating temperatures range from -20° to 50 °C

USER-FRIENDLY, LOW MAINTENANCE, EASY INSTALLATION

  • Up to 2 years between calibrations
  • Bump-test kit available
  • Low Maintenance and cleaning
  • Wireless connection
  • Site-specific interfacing and remote connections available
  • Self-cleaning/minimal maintenance: No pumps, no filters, and no user-serviceable parts.
  • Frequent blast action cleans dust from within the measurement chamber.
  • Easy to install (mobile/fixed). No on-site sensor calibration with installation

VISUAL ALERTS

  • Local visual indication via multi-colour LED status ring
  • Ambient TemperaturE

  • Humidity

  • Barometric Pressure

  • PM1

  • PM2.5

  • PM4

  • PM10

COMMUNICATION INTERFACES & PROTOCOL OPTIONS

  • Standard: RS-485 with Modbus RTU
  • Optional: Ethernet with PoE (IEEE 802.3) and Modbus TCP/IP
  • Wireless options: M3SH Private 5G
  • System integration: Suitable for PLC, SCADA, fire alarm, suppression and site-wide monitoring systems

MODELS

  • Intrinsic safeOperating voltage: 9-48 VDC or 85-265 VAC
  • Non-Intrinsic safeOperating voltage range 9-18VDC powered from an intrinsic safe power supply

Built-in heated chamber for enhanced performance in various conditions.

  • Mining And Surface Certification (MASC)

  • IP65 Rated (Waterproof & Dustproof)

 

       

 

  • Mining (surface & underground)
  • Manufacturing and heavy industry
  • Construction & tunneling sites
  • Stockpile domes and conveyors
  • All environment with hazardous dust particulates

 

 

MEASUREMENTS

RELATED PRODUCTS

D52 | DUST PARTICULATE MANAGEMENT

QUICK OVERVIEW

The D52 is designed for use in mining, manufacturing and construction, where the concentration and variability of airborne dust particles (PM1.0, PM2.5 & PM10.0) pose significant operational and health risks.

REAL-TIME MONITORING & REPORTING
  • Easy to read data readings and range limits display on an LCD-display: Time-weighted average (TWA) and particulate matter measured for 1μm, 2.5μm, and 10μm.
 CONFIGURABLE WIRED/WIRELESS REPORTING
  • SCADA Software enabled, including particulate matter readings per field unit and dust size grouping
  • Site-specific and remote connection options
  • Reliable data transfer via wired or wireless options:
    • Wired: RS485 (Modbus-RTU)
    • Wireless: IoT Network, Private 5G, GSM
  • Configurable to activate automated ventilation and dust suppression systems
  • Response time: <60 seconds

 

ACCURATE & CONNECTED
  • IoT-enabled with wireless and wired data transfer
  • Compatible with automated dust suppression and ventilation systems
  • Dust impactor and cyclone separation for enhanced accuracy

S50 | EARLY SMOKE & FIRE DETECTOR

 

S50 Early fire and smoke detector

Min Height: 333.3px

 

QUICK OVERVIEW

The S50 guarantees reliable early smoke and fire detection. Its easy integration activates an automatic fire suppression system to safeguard people, the environment and your assets. MOS, SO₂, CO, CO2, VOC sensing.

 

REAL-TIME MONITORING & FALSE ALARM DISCRIMINATION
  • Accurate, real-time, in-field measurements of hazardous gas ambient temperature and humidity
  • Follows NIOSH standards to reduce false alarms (Unlike traditional systems that rely on ionization or optical sensor
 CONVEYER BELT WEAR DETECTION
  • Achromatic detection: Proactive SO₂ and CO monitoring from high heat production caused by belt degradation, enabling early intervention before significant damage or risks arise.
MULTI-SENSING CAPABILITIES
  • MOS, SO₂, CO, CO2, VOC, Temperature, Relative Humidity
AUDIBLE & VISUAL ALERTS
  • 16 x 2 OLED Display to easily see measurements
  • 360° Configurable RGBY Strobe light to indicate alarm and no alarm
BATTERY BACK-UP
  • Built-in battery back-up (up to 8 hours)
  • Automatic charging when connected to a supply line
USER-FRIEDNLY & ROBUST
  • IP65 Rated (water & dust tight)
  • Operating temperatures range from -20°C to 70°C
  • Easy to install
WIRELESS/WIRED COMMUNICATION
  • RS485, Modbus-RTU
  • IoT
  • Private 5G Enabled
  • Built on open-integration standards

DPM50 | DIESEL PARTICULATE MONITOR

DPM50-side view

QUICK OVERVIEW

The DPM50 measures and analyzes diesel particulate matter (CO2, SOx, EC, PAH, NOx, VOC, O2, 03, CO, PM1, PM2.5, PM4, PM10, EC) emissions from diesel engines.: a significant concern due to their potential health and environmental impacts.

 

SMART LASER SENSING
  • Intelligent laser particle counting for PM1.0, PM2.5, PM10
  • Real-time data on TWA (time-weighted average)
USER-FRIENDLY & LOW MAINTENANCE
    • Self-cleaning, minimal maintenance (no pumps or filters)
    • No user-serviceable parts – designed for long life and low service requirements
    • Integrated 5” colour TFT LCD-display with visual indicators
    • User-friendly SCADA interface with real-time monitoring
    • Mobile and fixed installation options

     

    ACCURATE & CONNECTED
    • IoT-enabled with wireless and wired data transfer
    • Compatible with automated dust suppression and ventilation systems
    • Dust impactor and cyclone separation for enhanced accuracy

    P511 | AIR VELOCITY MONITORING

     

    QUICK OVERVIEW

    The P511  is our state of the art air velocity monitor, offering precise digital wind-speed measurements, with audible and visual indications and alerts.

     

    REAL-TIME MEASUREMENTS
    • Accurate: real-time air-velocity measurements
    • Response time: non-IS & Mains: 30 sec, EX ia:120 sec
    • Sensor range: 0 to 10m/s
    • Operating range: 0 to 10m/s
    ACCURATE & CONNECTED
    • Precise digital wind-speed measurements
    AUDIBLE & VISUAL ALERTS
    • Optional Audible (93dB) alert at configurable, pre-set levels
    • 360° Red red (alarm) and green (no alarm) light indication on device
    ROBUST 
    • Platinum sensors for long-term reliability in harsh environments
    • Operating temperatures range from -10°C to 50°C
    WIRELESS/WIRED COMMUNICATION
    • RS485, Modbus-RTU
    • IoT
    • Private 5G Enabled
    • Built on open-integration standards

    NM20/60 NOISE MONITORING

     

    QUICK OVERVIEW

    The NM20/30 & NM61 offer flexible and scalable noise monitoring networks to reduce long-term health effects caused by long-term noise exposure. Visual and audio alerts make quick response times easy.

     

    REAL-TIME MONITORING
    • Real-time sound level measuring and reporting for up to 10 NM20 sensors
    • 8-Hour time-weighted average tracking
      AUDIBLE & VISUAL ALERTS (IN-FIELD)
      • Optional Audible (93dB) alert at configurable, pre-set levels
      • 360° Red red (alarm) and green (no alarm) light indication on device
      ROBUST 
      • Platinum sensors for long-term reliability in harsh environments
      • Operating temperatures range from -10°C to 50°C
      WIRELESS/WIRED COMMUNICATION
      • RS485, Modbus-RTU
      • IoT
      • Private 5G Enabled
      • Built on open-integration standards